Fujitsu C122-E177-01EN ユーザーズマニュアル

ページ / 512
MMB CLI (Command Line Interface) Operations 
 
 
set active_mmb {0 | 1} {quiet} 
 
(2)  Option  
0: MMB#0 is specified  
1: MMB#1 is specified 
quiet: Command is executed without interacting with the user. 
 
(3)  Usage example 
None 
 
(4)  Message 
The following table lists the messages which are displayed in this CLI. 
 
For details of the messages, see the PRIMEQUEST 2000 Series Message Reference (C122-E178EN). 
 
The specified MMB#x is NOT present. 
The specified MMB#x is disabled. 
The specified parameter is invalid. 
Are you sure to continue set active mmb? [y/n]: 
set active_mmb failed. 
 
 
2.2.13 set date
 
Set the date and time. 
The set format is as following. 
 
 
MM : Month (01~12) 
 
DD : Date (1~28|29|30|31) 
 
hh : Time(00~23) 
 
mm : Minutes(00~59) 
 
CC : First two digits of the year (option) 
 
YY : Last two digits of the year (option) 
 
SS: Seconds (option) 
 
  Privilege: Administrator 
 
(1)  Input format 
 
set date MMDDhhmm{{CC}YY}{, SS} 
 
(2)  Option  
None 
 
(3)  Usage example 
None 
 
(4)  Message 
The following table lists the messages which are displayed in this CLI. 
 
For details of the messages, see the PRIMEQUEST 2000 Series Message Reference (C122-E178EN). 
 
The specified date is invalid. 
Unable to set date because NTP is enabled. 
Time synchronization was requested to Standby MMB. 
Unable to execute this command on a standby MMB.