Fujitsu C122-E177-01EN ユーザーズマニュアル

ページ / 512
MMB Web-UI (Web User Interface) Operations 
 
[Degraded]         : It shows that a failure has occurred in the component of a certain unit, and the unit is 
operated without disconnecting the failed component. It is shown by 
 icon. 
 
TABLE 1.15 Status of Unit and its Icons 
Status 
Display Color 
Icon 
Normal (Normal state) 
Green 
None 
Warning, Degraded 
Yellow 
Black ‘!’ mark in yellow triangle. 
 
Failed 
Red 
White ‘X’ in red circle. 
 
 
Each unit is linked with the window showing the detailed status. However, for units which are not mounted, 
there is no window showing the details. Therefore, these units are not linked. 
 
TABLE 1.16 Items displayed in [System Status] Window 
Items 
Description 
Power Supply 
Shows the status of PSU 
Fans 
Shows the status of FAN 
Temperature 
Shows the status of temperature sensor 
SB#0 ~ SB#3 
Shows the status of system board 
In case of PRIMEQUEST 2400E model, it is SB#0 ~ SB#1 
IOU#0 ~ IOU#3 
Shows the status of IOU 
DU#0 ~ DU#1 
Shows the status of DU 
OPL 
Shows the status of OPL 
MMB#0 ~ MMB#1 
Shows the status of MMB 
PCI_Box#0 ~ PCI_Box#3 
Shows the status of PCI_Box which are connected 
 
(1)  Menu Operation 
[System] – [System Status] 
 
(2)  Window Operations 
1. 
Click the link corresponding to each unit when the detailed status of unit is to be confirmed. The 
window showing detailed status of each unit appears. 
 
Remarks 
 
The detailed status can also be displayed by selecting the menu of target unit from [System] sub menu 
directly. For details on the operations, see 
”. 
 
1.2.2  [System Event Log] Window 
Among the events generated in the PRIMEQUEST 2000 series system, events of MMB and BMC stored in 
the current MMB system event log are displayed on the [System Event Log] window in chronological order. 
 
Maximum 32000 events can be stored in system event log. When the entries in the system event log are full, 
oldest event log is deleted, and latest event log is stored in system event log.