Emerson 752I ユーザーズマニュアル

ページ / 172
Monitor:
 Monitor Recovery and Updates
15-7
MONITOR RECOVERY AND UPDATES
Note:
The monitor provides VxWorks 6.0 support for Error Data and Reporting (EDNR). This feature allocates a per-
sistent area of memory that retains its contents after a systerm soft reset. Any information stored in the 32-
megabyte window starting at 0x1E000000 should stil be available after a soft resset.
This section describes how to recover and/or update the monitor, given one or more of the 
following conditions: 
• If there is no console output, the monitor may be corrupted and need recovering. 
• If the monitor still functions, but is not operating properly, then you may need to reset 
the environment variables. 
Recovering the Monitor
First, make sure that a monitor ROM device is installed in the PLCC socket. Then, place a 
jumper on JP2, across pins 1 and 2 (see 
). 
1
Issue the following command, where serial# is the four digit serial number, 683-xxxx:
[Katana 752i (1.0)] => moninit serial#
2
Reset the monitor:
[Katana 752i (1.0)] => reset
3
Reset the environment parameters:
[Katana 752i (1.0)] => envinit serial#
4
Power down the board and remove the jumper from JP2, pins 1 and 2.
Updating the Monitor via TFTP
To update the monitor, follow the steps below and insert the appropriate data in the itali-
cized fields.
1
If necessary, edit your network settings: 
[Katana 752i (1.0)] => setenv ipaddr 192.168.1.100 
[Katana 752i (1.0)] => setenv gatewayip 192.168.1.1 
[Katana 752i (1.0)] => setenv netmask 255.255.255.0 
[Katana 752i (1.0)] => setenv serverip 192.168.1.2 
Optionally, save your settings: 
[Katana 752i (1.0)] => saveenv 
2
TFTP the new monitor (binary) image to memory location 0x100000: 
[Katana 752i (1.0)] => 
tftpboot 100000 path/on/tftp/server/to/monitor.bin