HP (Hewlett-Packard) HP BladeSystem Enclosure technologies ユーザーズマニュアル

ページ / 28
 
Figure 13 lists the available configurations for half-height devices installed in device bay N (1–8). 
 
Figure 13. Port mapping for HP BladeSystem c3000 half-height server blades to interconnect bays 
 
 
Port mapping differs slightly between full-height and half-height server blades due to the support for 
additional mezzanine cards on the full-height version. HP has simplified the process of mapping 
mezzanine ports to switch ports by providing intelligent management tools through the Onboard 
Administrator and HP Insight Manager software. 
Virtual Connect 
With the c-Class architecture, HP introduced a new type of interconnect technology: Virtual Connect. 
As it is implemented in c-Class architecture, Virtual Connect technology provides virtualized server 
connections to the Ethernet (LAN) or Fibre Channel (SAN) networks. Virtual Connect technology 
virtualizes the server-edge so that networks can communicate with pools of HP BladeSystem server 
blades instead of the conventional one-to-one relationship.  
Virtual Connect consists of hardware (the Virtual Connect module) and a management agent that runs 
on the Virtual Connect module. Like Ethernet and Fibre Channel switches, the Virtual Connect modules 
slide into the interconnect bays of the c3000 Enclosure. The Ethernet module is necessary to install 
Fibre Channel because the Virtual Connect Manager software runs on a processor on the Ethernet 
module. The Ethernet module has sixteen 1-GbE downlinks to servers (connected across the signal 
midplane), eight 1-GbE uplinks to the network (RJ-45 copper Ethernet connectors), two 10-GbE 
connectors (for copper CX4 cables), and one 10-GbE internal inter-switch link (across the signal 
midplane) for a failover connection between Virtual Connect modules. The Fibre Channel module has 
sixteen 4-Gb Fibre Channel downlinks to servers and four 1/2/4-Gb auto-sensing Fibre Channel 
uplinks to the network.  
Virtual connect Ethernet modules can be used in interconnect bays 1, 2, 3 and 4 when Ethernet 
mezzanine cards are used in the appropriate mezzanine slot on the server blade. Virtual Connect 
Fibre Channel modules can only be used in interconnect bays 3 and 4 and require a Fibre Channel 
mezzanine card in Mezzanine slot 2 or 3 in the server blade. 