Omron C200HG ユーザーズマニュアル

ページ / 564
321
Indirect Destination Beginning Word Designations
D is used to specify the destination beginning word as follows when indirect
specification is designated:
12 to 15
08 to 11
04 to 07
00 to 03
D
Area type
0
Word no. (5th
digit)
D+1
Word no. (4th
digit)
Word no. (3rd
digit)
Word no. (2nd
digit)
Word no. (1st
digit)
Indirect designations depend on the series of the destination PC.
CV-series PCs
Addresses in parentheses are for the CV500.
Designation
Corresponding CV-series PC words
Area
Area
code
Word
number
Area
Word number
IR area
00
0 to 999
CIO Area
0 to 999
LR area
06
0 to 63
1000 to 1063
HR area
07
0 to 99
1064 to 1163
SR area
08
0 to 27
1164 to 1191
Timer area (PV)
03
0 to 1023
Timer Area
(PV)
0 to 1023 (0 to 511)
DM area
05
0 to 24575
DM Area
0 to 24575 (0 to 8191)
C-series PCs
Designation
Area
Area code
Word number
IR area
00
0 to 511
LR area
06
0 to 63
HR area
07
0 to 99
SR area
08
0 to 27
Timer area (PV)
03
0 to 511
DM area
05
0 to 6655
EM area
10 to 17 (Bank 0 to 7)
28 to 2F (Bank 8 to 15)
18
(Current bank)
0 to 6143
Indirect designations depend on the series of the destination PC.
CV-series PCs
Designation
Area
Area code
Word number
CIO Area
00
0 to 2555
CPU Bus Link Area
01
0 to 255
Auxiliary Area
02
0 to 511
Timer Area
03
0 to 1023
Counter Area
04
0 to 1023
DM Area
05
0 to 24575
EM Area
10 to 17:Bank 0 to 7
18: Current 
bank
0 to 32765
SYSMAC NET Link Systems
SYSMAC LINK/Ethernet
Systems
Network Instructions
Section 5-26