AMCC 9690SA ユーザーズマニュアル

ページ / 31
Chapter 3. Installing a Battery Backup Unit
24
3ware 9690SA SAS/SATA RAID Controller Installation Guide
Replacing the Battery
The Battery Backup Unit (BBU) will last for many years. The BBU 
battery has an expected life span of one to two years depending on 
usage.
You can check the current status of the battery, and test it. For 
details, see instructions in 3ware SAS/SATA RAID Software User 
Guide, Version 9.5.1
.
To replace the battery
1
Make sure the system is powered down, that you are grounded, 
and follow all appropriate safety procedures.
2
Disconnect the battery power cable from the BBU control 
module on the controller card. 
To do so, press down on the lever-like clip on the battery power 
connector and slide it out of the slot.
(If desired, you can remove the BBU control module to 
facilitate disconnecting the power cable. This will require 
removing the controller card from your enclosure.) 
Figure 17 shows how removing the connector looks if you 
remove the BBU control module from the controller.
Caution: 
There is a risk of explosion if the battery is replaced 
by an incorrect type. To obtain a replacement battery module, 
contact AMCC.
For proper battery disposal resources, contact RBRC, the 
Rechargeable Battery Recycling Corporation (
www.rbrc.com
).
Vorsicht: 
Es entsteht Explosionsgefahr bei Auswechslung der 
Baterie mit einer des falschen Typs. Um eine Ersatzbaterie zu 
erhalten, wenden Sie sich an die AMCC. 
Um Ressourcen zur korrekten Entsorgung der Baterie in 
Erfahrung zu bringen, wenden Sie sich an die RBRC (the 
Rechargeable Battery Recycling Corporation) (