Citizen CL-S631 ユーザーズマニュアル

ページ / 66
39
Printer Operation
7 Zebra
®
 Emulation
Mode Settings
[Zebra
®
 Emulation]
Top Menu
Sub Menu
Default
Menu
Remarks
Global
Config Set 1
Config Set 1
Sets the Config Set.
configuration
Config Set 2
Config Set 3
Page Setup
Print Speed
4 IPS
2 to 6 IPS
[For CL-S621]
Printing speed setting.
(5 or 6 IPS only in Direct Thermal mode.)
(2 to 4 IPS with optional peeler.)
4 IPS
2 to 4 IPS
[For CL-S631]
Printing speed setting.
Print Darkness
10
00 to 30
Print darkness setting
(printhead temperature)
Darkness Adjust
0
-10 to 10
Darkness command adjustment
Print Method
Thermal transfer Thermal transfer
Selecting thermal transfer (ribbon)
Direct thermal
/direct thermal media
Ribbon Winding
Outside
Outside
Selecting the ribbon winding direction.
Inside
Continuous Media
4.00 IN
0.25 to 32.00 IN
Setting default length of continuous
Length
101.6mm
6.40 to 812.8mm
media, if selected. ; the lower line is in metric
mode.
Vertical Position
0.00 IN
-1.00 to 1.00 IN
Print start position adjustment
0.0mm
-25.4 to 25.4mm
Horizontal Shift
0.00 IN
-1.00 to 1.00 IN
Horizontal printing location adjustment
0.0mm
-25.4 to 25.4mm
Vertical Image Shift
000dots
-120 to 120 dots
Adjust the off set value in vertical when
mapping data on a RAM.
Media Sensor
See Through
See Through
Label sensor selection
Reflect
None
Small Media
OFF
ON
Setting for small labels
Adjustment
OFF
Small Media
1.00 IN
0.25 to 1.00 IN
Setting length of small label media
Length
25.4mm
6.40 to 25.4mm
System Setup
Sensor Level
1.5V
0.0V to 3.3V
Setting the threshold of the sensor
Paper End Level
2.80V
0.01V to 3.00V
Sets the paper end level.
Error Reporting
On Printing
On Printing
Setting for error report.
Immediate
Buzzer Select
ON
ON
Setting buzzer sounding conditions
OFF
Metric/Inch
Inch
Inch
Setting the units used
mm
Max Media Length
10.00 IN
1.00 to 50.00 IN
Setting the maximum label length
254.0mm
25.4 to 1270.0mm
Settings Lock
Off
On
When on, prevents software commands from
Off
changing the values set by the VuePrint menu
Keyboard Lock
Off
On
Prevents the control panel from affecting
Off
the printer's configuration. (User "lock-out")
Media Power Up
Off
On
Selects whether or not to initiate media
Off
measurement when the power in ON.
CI Lock
Off
On
Activates/deactivates the CI command.
Off