Toshiba B-EX ユーザーズマニュアル

ページ / 95
 
77
[Sensor] 
Select a sensor to be used. 
Default None 
 
Options 
None, Reflective, Transmissive, Transmissive (Preprinted Labels),   
Reflective (Manual) 
 
[Issue Mode] 
Select an issue mode. 
Default Batch 
Options 
Batch, Cut After Every Page, Peel-off 
 
[Print Method] 
Select a print method. 
Default Thermal 
Transfer 
B-EX4T1-G / B-EX4T1-T: 
Thermal Transfer, Thermal Transfer (Ribbon Saving), Direct Thermal,   
Direct Thermal (Head Up) 
Options 
Other than B-EX4T1-G / B-EX4T1-T: 
Thermal Transfer, Direct Thermal 
 
[Label Length] 
Set the effective print length of media. 
Default 74 
mm 
Other than B-EX4T2-H:    8 to 1500 mm 
Range 
B-EX4T2-H:    8 to 500 mm 
 
[Label Gap] 
Set the length of the gap between labels. 
Default 2 
mm 
Range 
0 to 20 mm 
 
[Label Width] 
Set the effective print width of media. 
Other than B-EX6T2-G / B-EX6T2-T: 
Default 104 
mm 
Range 
10 to 104 mm 
B-EX6T2-G / B-EX6T2-T: 
Default 152 
mm 
Range 
10 to 152 mm 
 
[Tone Adjustment] 
Set a fine adjustment value for the print tone. 
A Print Density Fine Adjust command only for the selected print method is transmitted. The fine 
adjustment value set in the Print Density Fine Adjust command will be effective until it is changed. 
Default 0 
Range 
-20 to +10 
 
[Test Print] 
The printer performs a test print on the specified conditions. 
When this button is clicked, the processing starts. 
When Multi LAN is selected for the interface, the [Printer List] screen is displayed to allow choosing the 
printers on which the test print is performed. 
When the processing starts, the progress status screen is displayed.    When the processing is completed, 
the completion screen is displayed. 
This function is executed only when the printer is in online mode and idle state. 
When reading the file or creating an image data failed, the error message is displayed.