Zebra Technologies 2237A10L010 ユーザーズマニュアル

ページ / 230
Troubleshooting
RFID Problems
158
13383L-004 Rev. A
Xi
IIIPlus/R110Xi/R170Xi User Guide
9/6/07
RFID Problems
 identifies problems that may occur with RFID printers, the possible causes, and the 
recommended solutions. For more information about RFID, refer to the RFID Programming 
Guide. A copy of the manual is available at 
 or on the user CD 
that came with your printer.
Table 17 • RFID Problems
Problem
Possible Cause
Recommended Solution
The RFID-enabled 
printer voids every 
label.
The printer is not calibrated for 
the RFID label being used.
Manually calibrate the printer (see 
). 
The printer is set for the wrong 
tag type.
Set the correct tag type. Refer to the RFID 
Programming Guide
 for instructions.
The printer is unable to 
communicate with the RFID 
reader.
1.
Turn off (O) the printer.
2.
Wait 10 seconds.
3.
Turn on (I) the printer.
4.
If the problem persists, you may have a bad 
RFID reader or a loose connection between 
the RFID reader and the printer. Contact 
Technical Support or an authorized Zebra 
RFID service technician for assistance.
The settings are incorrect in 
your label designer software.
The software settings override the printer 
settings. Make sure that the software and printer 
settings match.
You are using an incorrect 
programming position, 
particularly if the tags being 
used are within printer 
specifications.
Do one or more of the following as necessary:
• Check the programming position being used 
with the ^RS command, or the program 
position setting in your label designer 
software. If the position is incorrect, change 
the setting. 
• Select RESTORE for the 
RFID TAG 
CALIB
 parameter.
You are sending RFID ZPL 
commands that are incorrect.
Refer to the RFID Programming Guide for more 
information about the ZPL commands for RFID. 
Radio frequency (RF) 
interference from another RF 
source.
Do one or more of the following as necessary:
• Move the printer away from fixed RFID 
readers or other RF sources.
• Make sure that the media door is closed at all 
times during RFID programming.