Multi-Tech Systems PN S000408C ユーザーズマニュアル
Chapter 5 – Remote Configuration
Multi-Tech Systems, Inc. MT5600BA-V92 User Guide
33
Changing the Remote Escape Character
To improve security, you can change a remote modem’s remote configuration escape character. The
remote configuration escape character is stored in register S13. The factory default is 42, which is the
ASCII code for the asterisk character (*). Setting S13 to 0 (zero) disables remote configuration entirely—
but if you do this remotely, you won’t be able to change it back remotely!
remote configuration escape character is stored in register S13. The factory default is 42, which is the
ASCII code for the asterisk character (*). Setting S13 to 0 (zero) disables remote configuration entirely—
but if you do this remotely, you won’t be able to change it back remotely!
1. Establish a remote configuration link with the remote modem as described in “Basic
Procedure.”
2. Type
ATS13=n, where n is the ASCII code for the new remote configuration escape
character, and then press E
NTER
.
3. Save the new value by typing AT&W and pressing E
NTER
.
4. Type
ATO<CR> to exit remote configuration.