Chapter 4 – Voice Commands 
Multi-Tech Systems, Inc. SocketModem MT5634SMIxx Reference Guide (S000263C) 
 
126    
AT+VSM=128, 7200, 128, 0; +VEM=FFFFFFFF8; +VSD=128, 50 
OK 
The modem agrees.  
AT+VSM=129, 7200, 0, 0  The PC changes its PC/modem interface rate to 38400 bps and selects a 
compression method with the least sensitive setting, with the goal of playing a 
message with less distortion, and at 7200 samples per second. (Assume that 
the PC issued a +VSM=? command earlier.) 
OK 
The modem agrees.  
AT+VLS=4 
The modem selects the speaker.  The modem had earlier reported that a 
speaker was available.  
OK 
The modem agrees.  
AT+VTX 
The PC selects the Voice Transmit mode.  
CONNECT 
The modem agrees.  
<Data> 
The PC delivers <DLE> shielded and silence compressed voice data across the 
PC/modem interface.  
<DLE> <ETX> 
The PC indicates the end of the Voice data stream.  
OK 
The modem indicates it is in Voice Command mode.  
AT+VLS=0 
The PC deselects all devices.  
OK The 
modem 
agrees. 
 
The PC switches to Data mode, Command mode, and autobauding enabled: 
 
AT+VIT=0; +VPR=0; +FCLASS=0 
OK The 
modem 
agrees. 
 
Answer Phone, Play Greeting Message, and Record Message Example 
Command Response 
AT+FCLASS=8; 
The DCE switches to Voice mode.  The DTE selects a fixed 
AT+VIT=60; 
DTE-DCE interface rate.  The DTE knows from the sample  
+VPR=16 
rate selected earlier and the bits-per-sample that the DTE-DCE interface rate 
should be 38400 bps.  The DTE-DCE Inactivity Timer starts with 60 seconds.  
OK 
DCE agrees (to the old DTE/DCE interface rate). 
AT+VSM=129, 7200, 0, 0  DTE changes its DTE/DCE rate to 38400 bps and selects a compression 
method with the least sensitive setting, with the goal of recording a message 
with less distortion, and at 7200 samples per second.  Assume that the DTE 
issued a +VSM=? command earlier.  
OK 
The DCE agrees. 
AT+VSD=127, 20  DTE selects a silence detection period of 2 seconds. 
AT+VLS=0 
DTE selects a silence detection period of 2 seconds with the least sensitive 
setting (for detecting the end of voice recording).  
OK 
The DCE agrees. 
AT+VIT=0; 
The DTE selects the Data mode with autobauding, and disables +VPR=0; 
automatic DCE answering. The DCE waits for a phone call.  
+FCLASS=0 
(not necessarily in Data mode). 
S0=0 
OK 
The DCE agrees. 
RING 
At some time, a remote station calls.   
AT+FCLASS=8; 
The DCE switches to Voice mode. The DCE selects a fixed AT+VIT=60; 
DTE/DCE Interface Rate. The DTE knows from the sample AT+VPR=16; rate 
selected earlier and the bits per sample that the DTE/DCE Interface Rate should 
be 38400 baud. The DTE/DCE Inactivity Timer starts with a value of 60 seconds.  
OK 
The DCE agrees (at the old DTE/DCE Interface Rate).  
AT+VLS=0 
The DTE selects all devices.