Chapter 1 – AT Commands, S-Registers and Result Codes 
Multi-Tech Systems, Inc. SocketModem MT5634SMIxx Reference Guide (S000263C) 
 
17    
 
Command:
 
%En 
Fallback and Fall Forward Control 
Values:   n = 0, 1, or 2 
Default:   2 
Description:   
%E0 
Disable fallback and fall forward. 
 
 
%E1 
Enable fallback, disable fall forward. 
 
 
%E2 
Enable fallback and fall forward. 
 
 
Command:  %Hn 
Direct Connect Enable 
Values:   n = 0, 1 
Default:   0 
Description:   
%H0 
Sets callback security to normal operation. 
 
 
%H1    All callback security calls will be direct connect regardless of whether the 
password or phone number has the - character. 
 
 
Command: %Rn Cisco 
Configuration 
Values:   n = 0, 1 
Default:   0 
Description:  
%R0  Disables Cisco configuration. 
  
%R1 
Sets 
E0Q1&D0, \N0$SB9600, and %S1 for operation with a Cisco 
router. 
 
 
Command: %Sn
 
Command Speed Response 
Values:   n = 0, 1 
Default:   0 
Description:   
%S0 
Sets modem to respond to AT commands at all normal speeds. 
 
 
%S1 
AT commands accepted at 115200 bps only. Commands at other speeds 
are ignored. 
 
 
 
 
   
Command: $D
DTR Dialing 
Values:   n = 0 or 1 
Default:   0 
Description:   
$D0 
Disables DTR dialing. 
 
 
$D1 
Dials the number in memory location 0 when DTR goes high. 
 
 
Command: $EBn
 
Asynchronous Word Length 
Values:   n = 0 or 1 
Default:   0 
Description:   
$EB0  Enables 10-bit mode. 
 
 
$EB1  Enables 11-bit mode. 
 
 
Command: $MBn  Online BPS Speed 
Values: n 
= speed in bits per second 
Default: 28,800 
Description: 
$MB75 
Selects CCITT V.23 mode 
 
$MB300 
Selects 300 bps on-line 
 
$MB1200 
Selects 1200 bps on-line 
 
 
$MB2400 
Selects 2400 bps on-line 
 
 
$MB4800 
Selects 4800 bps on-line 
 
 
$MB9600 
Selects 9600 bps on-line 
 
 
$MB14400 
Selects 14400 bps on-line 
 
 
$MB19200 
Selects 19200 bps on-line 
 
 
$MB28800 
Selects 28800 bps on-line 
 
 
$MB33600 
Selects 33600 bps on-line