Multi-Tech Systems MT5634SMI V.92 ユーザーズマニュアル

ページ / 136
Chapter 1 – AT Commands, S-Registers and Result Codes 
Multi-Tech Systems, Inc. SocketModem MT5634SMIxx Reference Guide (S000263C) 
 
28    
 
S-Registers 
Certain modem values, or parameters, are stored in memory locations called S-Registers. Use the S 
command to read or to alter the contents of S-Registers (see previous section). 
Register Unit 
Range 
Default  Description 
S0 
1 ring 
0, 1–255 
Sets the number of rings until the modem answers. ATS0=0 
disables auto answer completely.  
S1 
1 ring 
0–255 
Counts the rings that have occurred. 
S2 
decimal  0–127 
43 (+) 
Sets ASCII code for the escape sequence character. 
 
 
128–255 
 
Values greater than 127 disable escape. 
S3 
decimal  0–127 
13 (^M)  Sets the ASCII code for the carriage return character. 
S4 
decimal  0–127 
10 (^J) 
Sets the ASCII code for the line feed character. 
S5 
decimal  0–32 
8 (^H) 
Sets the ASCII code for the backspace character.  
  
 
33–127 
 
Values greater than 32 disable backspace. 
S6 
seconds  2–65* 
2* 
Sets the time the modem waits after it goes off-hook before it 
begins to dial the telephone number. 
S7 
seconds  35-65* 
50* 
Sets the time the modem waits for a carrier signal before 
aborting a call. Also sets the wait for silence time for the @ dial 
modifier. 
S8 
seconds  0–65 
Sets the length of a pause caused by a comma character in a 
dialing command. 
S9 
decimal  0, 1–127 
37 (%) 
Sets ASCII code for remote configuration escape character. 
S9=0 disables remote configuration. 
S10 
100 ms 
1–254 
20 
Sets how long a carrier signal must be lost before the modem 
disconnects.  
S11 
1 ms 
50–150* 
95* 
Sets spacing and duration of dialing tones. 
S28 
decimal  0, 1–255 
0 disables, 1–255 enables V.34 modulation.  
S30  
1 minute  0, 1–255 
Sets the length of time that the modem waits before 
disconnecting when no data is sent or received. A value of 
zero disables the timer. See also the \T command 
S35 
decimal  0–1 
0 disables, 1 enables the V.25 calling tone, which allows 
remote data/fax/voice discrimination. 
S36 
decimal  0–7 
Specifies the action to take in the event of a negotiation failure 
when error control is selected. (See S48.)