Multi-Tech Systems MT5634SMI V.92 ユーザーズマニュアル

ページ / 136
 
 
Chapter 2 – Fax Class 1 and 1.0 Commands 
Multi-Tech Systems, Inc. SocketModem MT5634SMIxx Reference Guide (S000263C) 
 
39    
Result Codes:   
CONNECT – Reported when the modem begins the training sequence after 
receipt of a valid <mod> value. 
 
 
ERROR – If the modem transmit buffer becomes empty and the last 
transmitted character is NUL (00), the modem continues to transmit NULs 
until the DTE sends more data or five seconds elapses. After five seconds 
elapse with an empty transmit buffer, the modem will turn off the transmit 
carrier, return to the command state, and report the ERROR result code. 
 
 
OK – If the modem’s transmit buffer becomes empty and the last transmitted 
character is not NUL, the modem will turn off the transmit carrier, return to the 
command state, and report the OK result code. 
Reporting Current or Selected Values: 
  
Command: 
+FTM? 
 
 
Response: +FTM: <mod> 
 
 
Example: +FTM: 98 For V.17 9600 bps. 
Reporting Supported Range of Parameter Values: 
  
Command: 
+FTM=? 
 
 
Response: +FTM: (<mod> range) 
 
 
Example: +FTM: 3,24,48,72,73,74,96,97,98,121,122,145,146 
 
 
Command: +FRM  Receive 
Facsimile 
Description: 
 
This command causes the modem to enter the receiver mode using the 
modulation defined below.  
Defined Values:  
<mod> Decimal number corresponding to the selected modulation mode and 
data rates shown in Table 3-2. 
Reporting Current or Selected Values: 
  
Command: 
+FRM? 
 
 
Response: +FRM: <mod> 
 
 
Example: +FRM: 98 for V.17 9600 bps. 
Reporting Supported Range of Parameter Values: 
  
Command: 
+FRM=? 
 
 
Response: +FRM: (<mod> range) 
 
 
Example: +FRM: 3,24,48,72,73,74,96,97,98,121,122,145,146 
Result Codes:   
CONNECT – Reported when the selected carrier is detected. 
 
 
+FCERROR – Reported if another carrier is detected and FAR=0; the modem 
then returns to the command state. 
 
 
NO CARRIER – Reported if loss-of-carrier is detected. 
 
 
OK – Reported if the DTE sends any character to the modem other than XON 
or XOFF while operating in configured flow control from the DTE; the modem 
then returns to the command state.