Multi-Tech Systems MT5634SMI V.92 ユーザーズマニュアル
Chapter 3 – Fax Class 2 Commands
Multi-Tech Systems, Inc. SocketModem MT5634SMIxx Reference Guide (S000263C)
85
Adaptive Answer
Class 2.1
+FAA
Write syntax:
+FAA=<value>
Valid values:
0, 1
Default value: 0
+FAA=0
The modem shall answer only as a Class 2.1 facsimile device. No
automatic switching of service class shall occur based on the calling
device type.
automatic switching of service class shall occur based on the calling
device type.
+FAA=1
The modem can answer and automatically determine whether to answer
as a facsimile modem or as a data modem. If the modem automatically
switches, it resets the +FCLASS parameter to 0. +FCLASS does not
affect switching to Class 2.1 from other classes or switching to classes
other than Class 0.
as a facsimile modem or as a data modem. If the modem automatically
switches, it resets the +FCLASS parameter to 0. +FCLASS does not
affect switching to Class 2.1 from other classes or switching to classes
other than Class 0.
Note:
If the modem reconfigures itself to data modem operation in
adaptive answering, the host must reissue a new
+
FCLASS
=
2.1
command to enable subsequent Service Class 2.1 facsimile operation.
Class 2
+FAA
Write syntax:
+FAA=<value>
Valid values:
0, 1
Default value: 0
+FAA=0
Constrains the modem to answer as set by +FCLASS.
+FAA=1
The modem can answer and automatically determine whether to answer
as a facsimile modem or as a data modem. If the modem automatically
switches, it modifies FCLASS as appropriate.
as a facsimile modem or as a data modem. If the modem automatically
switches, it modifies FCLASS as appropriate.
Host Phase C Response Timeout, +FCT
Write syntax:
+FCT=<value>
Valid values:
0–255 in 100-millisecond units.
Default value: 30
This determines how long the modem waits for a command after reaching the end of
data when transmitting in Phase C. When this time-out is reached a cancellation
signal and then a +FHS:43 is issued to the host and the remote side is sent a
disconnect frame.
data when transmitting in Phase C. When this time-out is reached a cancellation
signal and then a +FHS:43 is issued to the host and the remote side is sent a
disconnect frame.
+FPHCTO, Host Phase C Response Time-out
Class 2.1/2.0
Not Applicable
.
Class 2
Syntax:
+FPHCTO=<value>
Value Values: 0 – 255
Default Value: 30
Default Value: 30
+FPHCTO=? 0-255 +FPHCTO? 30 Default value. Range: 0 - 255
This command specifies the waiting period during a fax transmission beyond which
the transmission is automatically terminated with an end-of-page command.
This command specifies the waiting period during a fax transmission beyond which
the transmission is automatically terminated with an end-of-page command.