Zhone Technologies 4821-A2 ユーザーズマニュアル

ページ / 54
Installation
14
BitStorm 4800 Express Model 4821-A2 Installation Guide
4821-A2-ZN21-30
Preparation
Consider the following before installing the BitStorm 4800 Express IP 
DSLAM:
z
Installation Site 
Your installation site should be well ventilated, clean, and free of 
environmental extremes. 
z
Installation Options
The BitStorm 4800 Express may be: 
— Mounted with the included mounting brackets in a standard 19-inch 
(483 mm) or 23-inch (584 mm) rack (including both Bay Networks 
and Nortel 23-inch racks), or, with separately purchased mounting 
brackets, in a 21-inch (535 mm) ETSI rack. ETSI brackets are 
available from Paradyne. See 
As many BitStorm 4800 Express units may be mounted in a standard 
rack as there are 1.75-inch (44.45 mm) spaces in the rack, so long as 
adequate cooling is provided.
— Mounted vertically against a wall.
The standard mounting brackets provided can be fastened to the base 
of the unit for wall mounting.
— Set on a shelf or desktop. 
Up to five BitStorm 4800 Express units may be stacked on a shelf or 
desktop. 
z
Power 
The BitStorm 4800 Express operates from a 90 to 265 VAC, 47 to 63 Hz 
power source.
z
Cabling
No cable except the power cable is provided with the BitStorm 4800 
Express. See 
, to determine what cables you 
need to procure before installation.