RF400 Series Spread Spectrum Data Radio/Modems
5
apx
TECHNOLOGIES INC.
CLASS 2 TRANSFORMER
MODEL NO: 
AP2105W
INPUT:
120VAC 60Hz 20W
LISTED
2H56
E144634
MADE IN CHINA
OUTPUT:
12VDC      1.0A
HICKSVILLE, NEW YORK
UL
R
UL
R
RS232
DC
Pwr
CS I/O
Pwr/TX
RX
MADE IN USA
Serial #
Program
Antenna
14320
RF400
Spread Spectrum Radio
This device contains transmitter module:
FCC ID: OUR-9XTREAM
The enclosed device complies with Part 15 of the
FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, 
and (2) this device must accept any intererence 
received, including interference that may cause
undesired operation.
Logan, Utah
RS232
DC
Pwr
CS I/O
Pwr/TX
RX
MADE IN USA
Serial #
Program
Antenna
14320
RF400
Spread Spectrum Radio
This device contains transmitter module:
FCC ID: OUR-9XTREAM
The enclosed device complies with Part 15 of the
FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, 
and (2) this device must accept any intererence 
received, including interference that may cause
undesired operation.
Logan, Utah
SE
DIFF
G
G
H
L
1
2
1
AG H
L
AG H
L
AG E1
AG E2 G
3
4
2
5
6
3
SE
DIFF
G
G
H
L
7
8
4
AG H
L
AG H
L
AG E3
AG G
G
9
10
5
11
12
6
P1 G
P2
G C8 C7 C6 C5 C4 C3 C2 C1
G 12V 12V
SDM
5V 5V G
G
SW 12V
SW 12V CTRL
Logan, Utah
G
12V
POWER
IN
CR10X WIRING PANEL
MADE IN USA
WIRING
PANEL NO.
EARTH
GROUND
CS I/O
FIGURE 2.  RF400 Basic Point-to-Point Network
Step 2 – Set Up Remote RF400
a.
Connect an antenna (or antenna cable with yagi or omni directional
antenna attached) to the RF400 antenna jack.  The separation between the
base RF400 antenna and the remote RF400 antenna can be any convenient
distance.
b.
Connect SC12 serial cable from datalogger CS I/O port to remote RF400
CS I/O port.  Current datalogger/wiring panel CS I/O ports apply power to
the remote RF400.
With older dataloggers lacking 12 V on pin 8 (see Table 1), you can
power the RF400 using a Field Power Cable (see above hardware list)
between the datalogger’s 12 V (output) terminals and the RF400’s “DC
Pwr” jack.
TABLE 1.  Lacking 12 V on CS I/O Pin 8
EQUIPMENT
SERIAL NUMBER
CR500
< 1765
CR7 700X Bd.
< 2779
21X
< 13443
CR10 Wiring Panels
All (black, gray, silver)
PS512M Power Supply
< 1712
When you connect power to the RF400 (through the SC12 cable or the
optional Field Power Cable) you should see the power-up sequence of red
and green LEDs described in Step 1 (assuming datalogger is powered).
LoggerNet or PC208W
AC Adapter
RS-232
CS I/O
Datalogger CS I/O