6.6.2.   Ring Indicate  
 
The Enabler II-G A-GPS module is capable of using the Ring line to discern the type of 
incoming call.  The indicator can be monitored via a hardware line available on the 60-pin I/O 
signal connector.  The Ring Indicator pin is #49.  
 
 
The function of the Ring line depends on the type of the call received. 
 
When the module is receiving a voice call, the Ring line goes low for 1 second and high for 
another 2 seconds.  Every 3 seconds the ring string is generated and sent over the Receive 
(Data Out) (Rx) line.  If there is a call in progress and call waiting is activated for a connected 
handset or hands free device, the Ring pin switches to ground in order to generate acoustic 
signals that indicate the waiting call. 
 
 
 
 
 
 
 
When a Fax or data call is received, Ring goes low and will remain low.  Every 3 seconds a 
ring string is generated and sent over the Receive (Data Out) (Rx) line. 
 
 
 
 
 
 
 
An incoming SMS can be indicated by an Unsolicited Result Code (URC) which causes the 
Ring line to go low for 1 second only.  Using the AT+CNMI command, the Enabler II-G A-
GPS module can be configured to send or not to send URCs upon the receipt of SMS.  See 
Enfora GSM/GPRS OEM Module AT Command Set Reference - GSM0102PB001MAN
 
 
 
 
 
 
1 second 
2 seconds
1 second
2 seconds
RING String RING 
String
Ring 
3 seconds
RING String 
RING String
Ring 
3 seconds
RING String
1 second 
URC 
Ring 
 
 
 
Figure 8 Ring Indicate Timing 
 
 
6.6.3.  Using the Power Control Signal 
 
Figure 9 shows a typical connection to the Enfora Enabler II-G A-GPS module in a machine-to-machine application 
using the external PWR_CTL_SIGNAL solution, where there is no external processor controlling the I/O, serial, or 
power on/off states.  RTC deep sleep functions will NOT function since the PWR_CTL_SIGNAL pin is tied low, the 
processor will never stay in a “RTC Sleep” mode.  To reset the module, power (BATT) must be cycled.  VBAK 
must be connected to an uninterruptible power source if RTC time is to be retained. 
MLG0208PB001 
27 
Version1.01 – 10/3/2006