MRV Communications TS5000/4U1/V*) ユーザーズマニュアル

ページ / 87
M R V   C o m m u n i c a t i o n s ,   I n c .   –   I n s t a l l a t i o n   M a n u a l  
6 
 
Back Panel Description 
 
Table 2:  TS5000/G Back Panel Controls, Interfaces, and Indicators 
Power
 
Power source Terminal Block (Main or UPS). 
AC power supply (100 to 240 Vac) or DC power 
supply (35 to 60 Vdc) 
 
Fiber optic 
 
Fiber Optic interface for connection to the 
peripheral equipment. The standard interface is MM 
850nm SC connector; other interfaces are available 
upon request (refer to price list or data sheet). 
In model TS5000/G-F with the fusion option, there 
are two fiber optic interface ports for connection to 
the Fusion system; one primary and the other 
redundant. 
 
Remote Monitor 
Connection to an optional Remote Status Monitor 
(RSM) or to RSM-DC (for Dry Contact connection) 
(not included in the standard transceiver kit)  
 
Connectors
 
Management 
 
Connection to 10Base-T SNMP management 
interface.  Pins 1,2: TX and 3,6 RX. 
Pins (4,5) and (7,8) of this connector can be used for 
dry contact purposes, for Airlink flag and F/O flag 
alarms respectively 
 
 
Note:
  Pins (4, 5) and (7, 8) of the management RJ45 connector can be used for dry contact 
purposes, for Airlink flag and F/O flag alarms respectively. 
 
 
Alignment Telescope
 
For fine alignment. 
 
 
Power Supply 
Pluggable AC power supply (100 to 240 Vac) or 
DC power supply (35 to 60 Vdc)  
 
Power 
Slot for Power Supply 
This slot can house an additional power supply to 
be fed from backup voltage source. This can be 
independent of primary voltage source for 