Figure 2.2:  Acceptable Mounting 
Figure 2.3 shows an unrecommended TereScope  link location because of 
interference by IR. Notice that the TereScopes are mounted far from the rooftop 
edges or are too close to the ground.
 
 
Figure 2.3:  Unrecommended Mounting 
Figure 2.4 shows an unacceptable TereScope  link location because of interference by 
passing vehicles. Notice that the TereScopes are mounted far from the rooftop 
edges and not high enough above the ground. 
TereScope  not at edge of roof.
 
TereScope  not at edge of roof.
 
Beam path passes too close to ground. Heat rising causes scintillation. 
Allow 4.5 m (15 ft) between ground and beam path.
Less than 4.5 m (15 ft) between beam 
path and heat-emitting surface.
Beam path more than 
4.5 m (15 ft) above 
surface to avoid traffic 
and rising heat.
TereScope  at edge of roof so 
that heat rising from roof 
surface does not affect beam