M R V   C o m m u n i c a t i o n s ,   I n c .   –   I n s t a l l a t i o n   M a n u a l  
32 
Bench Test 
It is always easier and more convenient to locate a failure and 
solve a problem in a lab on a bench than on a roof under bad 
conditions.  It is then strongly recommended, as the 
circumstances allow it, to perform a bench test with all the 
modules prior to the installation in order to check the equipment 
compatibility and to validate the configuration. 
See Unpacking Instructions in Appendix C. 
1 - TS5000/G & TS5000/G-F
 
Compatibility 
 
 
Peripheral equipment 
Check the operating of the peripheral equipment connecting them through cables 
(see Configuration 1 below). 
 
Interfaces 
Check the specifications compatibility (type, wavelength, receiver range, output 
power, data rate) between the TereScope and the peripheral equipment interfaces. 
Testing equipment 
Chose an appropriate BER (Bit Error Rate) tester for checking the physical link 
quality. A portable one is preferred for convenient use in the field.  
 
For example: A smartbit Giga Ethernet tester. 
A ping test or a file transfer between two workstations - connected to the 
networking equipment - is useful and easy to implement for testing the 
performance of the whole configuration. 
 
Setup 
Dip-switch 
Set all the DIP switch toggles to the OFF position for normal operation.  
 
 