MRV Communications TS5000/XXX (TS5000G/XYZ/V** ユーザーズマニュアル

ページ / 87
M R V   C o m m u n i c a t i o n s ,   I n c .   –   I n s t a l l a t i o n   M a n u a l  
34 
 
Interfaces 
Check the specifications compatibility (type, data rate) between the TereScope and 
the peripheral equipment interfaces. 
 
Testing equipment 
 
Chose an appropriate BER (Bit Error Rate) tester for checking the physical link 
quality. A portable one is preferred for convenient use in the field.  
 
A ping test or a file transfer between two workstations - connected to the 
networking equipment - is useful and easy to implement for testing the 
performance of the whole configuration. 
Setup 
Dip-switch 
Set all the DIP switch toggles (other than 8 and 10 which are for SNMP 
management and Fusion) to the OFF position for normal operation.  
 
 
4 - TS5000/4U1 
Compatibility 
 
 
Peripheral equipment 
Check the operating of the peripheral equipment connecting them through cables 
(see Configuration 1 below). 
 
Interfaces 
Check the specifications compatibility (type, standard compliance) between the link 
and the peripheral equipment interfaces. 
Testing equipment 
Chose an appropriate BER (Bit Error Rate) tester for checking the physical link 
quality. A portable one is preferred for convenient use in the field.  
 
Dip-switch Setup 
•  Main Dip-Switch: Set all the DIP switch toggles (other than 8 and 10 
which are for SNMP management and Fusion) to the OFF position 
for normal operation. 
•  Dip switch under the port in use: - switches 3&4 OFF for normal 
operation.  
Line coding (AMI or HDB3) – Toggle 1. 
- Receive Sensitivity (Short/Long Haul) – Toggle 2. 
- Impedance (75 ohm/120 ohm) – Toggle 5.