Mass storage devices
NOTE:
Each hard drive spare part kit and solid-state drive spare part kit includes a cable and bracket.
Description
Spare part number
Hard drive (select models only)
 
250-GB, 5400-RPM
537635-001
160-GB, 5400-RPM
537634-001
Hard Drive Hardware Kit
537641-001
Solid-state drive
 
64-GB
537640-001
32-GB
537639-001
16-GB
537638-001
8-GB
537637-001
Solid–state Drive Hardware Kit
537642-001
 
 
Before removing the hard drive or solid-state drive, follow these steps:
1.
Shut down the device. If you are unsure whether the device is off or in Hibernation, turn the device
on, and then shut it down through the operating system.
2.
Disconnect all external devices connected to the device.
3.
Disconnect the power from the device by first unplugging the power cord from the AC outlet and
then unplugging the AC adapter from the device.
4.
Remove the battery (see 
5.
If your device has WWAN capability, remove the SIM (see 
.
6.
Remove the keyboard (see 
To remove the mass storage assembly:
1.
Loosen the Phillips SP2.5×10.0 captive screw (1), and remove the two Phillips PM2.0×5.0
screws (2) that secure the assembly to the device.
Component replacement procedures
45