Psion Teklogix 7530 G2 ユーザーズマニュアル

ページ / 296
Psion Teklogix 7530 G2 Hand-Held Computer User Manual
167
Chapter 5: Configuration
Decoded (Internal) Scanners
2D UPC Half Block Stitching (
SE2223 only)
Setting this parameter to on enables “UPC Half Block Stitching” for the SE 3223 
omnidirectional engine only.
5.11.3.12 Codabar
Enabled
Set this parameter to on to enable “Codabar”.
Set Length L1 And Set Length L2
Lengths for “Codabar” can be set for Any lengthLength within a rangeOne 
discrete length 
or Two discrete lengths. The length of a code refers to the number of 
characters (i.e., human readable characters), including check digit(s). 
Double-tapping on this parameter displays a dialog box labelled Set Code Lengths 
where you can define the code length that will be recognized by your scanner.
Choosing One discrete length allows you to decode only those codes containing a 
selected length. Choosing Two discrete lengths allows you to decode only those 
codes containing two selected lengths. Length within a range allows you to decode 
a code type within a specified range from 5 to 55.
CLSI Editing
When enabled, this parameter strips the start and stop characters and inserts a space 
after the first, fifth, and tenth characters of a 14-character Codabar symbol. 
Note: Symbol length does not include start and stop characters.
NOTIS Editing
When enabled, this parameter strips the start and stop characters from decoded 
Codabar symbol.
Field Size/Chars
Refer to page 148 for details.
5.11.3.13 Code 93
Enabled
Set this parameter to on to enable “Code 93”.