Psion Teklogix 7530 G2 ユーザーズマニュアル

ページ / 296
Psion Teklogix 7530 G2 Hand-Held Computer User Manual
181
Chapter 5: Configuration
Decoded (Intermec ISCP)
Check Digit Verification
When enabled, this parameter checks the integrity of an I 2 of 5 symbol to ensure it 
complies with a specified algorithm: either USS (Uniform Symbology 
Specification) or OPCC (Optical Product Code Council).
Transmit Check Digit
If the check digit is to be transmitted with the data, this parameter must be enabled.
Set Length L1, Set Length L2, And Set Length L3
Lengths for “Codabar” can be set from 0 to 255. The length of a code refers to the 
number of characters (i.e., human readable characters), including check digit(s). 
Double-tapping on these parameters displays dialog boxes where you can define the 
code length that will be recognized by your scanner.
Length Mode
You can choose to set L1 as Minimum Length or L1,L2,L3 as Fixed Length.
Field Size/Char
Refer to page 148 for details.
5.11.4.11 Code 93
Enabled
Set this parameter to on to enable “Code 93”.
Minimum Length
Minimum lengths for the bar code can be set from 0 to 255. The length of a code 
refers to the number of characters (i.e., human readable characters), including 
check digit(s). 
Field Size/Char
Refer to page 148 for details.
5.11.4.12 Code 11
Enabled
Set this parameter to on to enable “Code 11”.