Toshiba E6581830 ユーザーズマニュアル

ページ / 51
 
E658130 
- 35 - 
6. 
Programming examples 
This chapter provides programming examples which control the inverter with the PLC. 
 
Item 
Programming Example 
Refer to Page
Reading the inverter status 
Reading the inverter status from the buffer   
memory of the master station. 
Setting the command mode 
Command mode from CC-Link is confirmed. 
Setting the operation commands   
Commanding the forward rotation. 
Setting the reference frequency   
Setting to 50.00Hz. 
Setting the monitoring function 
Monitoring the output frequency. 
Writing a parameter value 
Setting the f311 [Reverse-run prohibition   
selection] to [1 : Prohibit reverse run]. 
Reading a parameter value 
Reading the parameter f311. 
Reading the the fault record 
Reading the fault record 
Inverter reset 
Resetting the inverter. 
 
System configuration for programming example 
 
PS        Q02          QJ61          Input            Output 
Unit      CPU        BT11N        Unit              Unit   
         
 
(X/Y00    (X20      (Y30 
                                to 1F)        to X2F)        to 3F) 
Master unit 
Station 1   
Inverter
Station 2   
Inverter
X0020 
CC-Link communication cable 
 
Y30 
 
 
The example of CC-Link communication network composition 
CPU                                        Mitsubishi Electric Corp.   
Q02CPU 
Master unit               Mitsubishi Electric Corp.  
QJ61BT11N 
Input module            
Mitsubishi Electric Corp.  
QX40 
Output module            Mitsubishi Electric Corp. 
QY40P 
CC-Link dedicated cable   
Kuramo Electric Corp. 
FANC-110SBH 
Inveter                   Toshiba 
 
TOSVERT VF-S15(2 uints) 
One station is occupied
 
CC-Link option          
Toshiba 
 
CCL003Z(2 units)