Chaparral G5312/G7313 ユーザーズマニュアル

ページ / 160
 Managing 
Spares
6-5
Managing the Spare Pool
The spare pool lets you have one or more disk drives available for the reconstruction 
of redundant arrays (Mirrored [RAID 1 and RAID 10] and Parity [RAID 3, RAID 4, 
RAID 5, and RAID 50]) arrays. Once you assign a drive to the spare pool, it is not 
available for use as an array member or as a dedicated spare. 
If a pool spare is too small (smaller than an individual member in an array), the 
controller cannot use it. 
Adding a Spare to the Spare Pool
You can add up to eight drives to the spare pool to reconstruct any critical array on the 
controller. After an array has started using a pool spare, other critical arrays are 
prevented from using it. For a pool spare to be used, it must be at least as large as the 
minimum drive size in the array.
To add a pool spare:
1
From the System Menu, select Pool Spare Menu and press Enter.
The Pool Spare Menu screen displays.