Carrier Access Axxius 800 ユーザーズマニュアル

ページ / 568
Axxius 800 - Release 2.2
10-9
OCU-DP Card
LEDs
LEDs
There are two LEDs for each channel on the OCU-DP card. The function for each LED 
is listed below:
State
Description
Yellow Flickering
ALL
Boot Software in control.
Green (walking down) 
Red (walking up)
ALL
Application Software in control
 (repeated 3.5 times).
Red, slow flash
ALL
In Boot. Application flash code checksums 
did not match and Boot is waiting for 
application download.
Red
ALL
In Application code waiting for Controller to 
issue SW/HW revision request. This is the 
first request that comes from the OCU-DP 
card manager in the Controller.
Green
Yellow
Top
Bottom
Port in Self-test. Duration is 5-8 seconds.
Off
Top
Bottom
Port is set down (Out-Of-Service).
Green
Top
Port is receiving valid signals.
Red
Top
Port is receiving no signal (primary) or no 
frame sync (secondary or clear channel).
Red Flashing
Bottom
Port is receiving bipolar violations
Yellow
Bottom
Port is in loopback.