Carrier Access Axxius 800 ユーザーズマニュアル

ページ / 568
2-4
Axxius 800 - Release 2.2
Physical Installation
Assembly of Axxius 800
Assembly of Axxius 800
The cards should be positioned according to the following guidelines:
l
Power Supply(s) 24 or 48 VDC
Single Power Supply - slot Power 1 or Power 2
Dual Power Supplies - slot Power 1 and Power 2
l
Controller card(s) DS1 or DS3
Single controller card - slot A1 or A2
Dual controller cards - slot A1 and A2
l
Interface card
The Interface card is designed with two boards that follow a single guide. 
l
Service Cards can be in any slot 1 through 8. 
Note: Cards that use the front cable connections should be loaded from Slot 8 
to 1. This will minimize card access issues due to cable interference. 
l
Relay Card in the Relay slot.
l
Always install blank faceplates in any unused slots.
Controller
 
Interface
Card
Cards
(A1 & A2)
Service Card
Slots 1-8
Power
Supplies
(P1 & P2)
Future Development
Relay
Card