The Test Button
AXIS 1650 User’s Manual
61
Section 10
The Test Button
Factory Default
The test button is located on the front right hand side of the print server 
and is used to perform a Factory Default:
1. Remove the power adapter to switch off the print server.
2. Press and hold down the test button, while you reconnect the power 
adapter. 
3. Continue to hold down the test button until the network indicator 
remains constantly lit. This should take about 20 seconds.
4. Restart the print server by disconnecting and reconnecting the power 
adapter.
Important:
Canon BubbleJet
Printers
If the AXIS 1650 is connected to a Canon BubbleJet printer, the test 
button can be used for the following operations:
Print a Test Page
Press the test button 
once to print a test page. The test page contains 
basic information about the print server. It is recommended that you 
print a test page every time you connect the print server to a printer
Perform a Factory Default
See description above.
A factory default will reset all print server parameters and settings to 
their default values except Node address (NODE_ADDR.) 
The IP address (INT_ADDR.) will be reset to default 
192.168.0.90