9.2  Addressing Modes
9.2.1  Source Immediate
The result of an instruction using this addressing mode is placed
in the A register, the F register, the SP register, or the X register,
which is specified as part of the instruction opcode. Operand 1
is an immediate value that serves as a source for the instruction.
Arithmetic instructions require two sources; the second source is
the A, X, SP, or F register specified in the opcode. Instructions
using this addressing mode are two bytes in length.
Examples
9.2.2  Source Direct
The result of an instruction using this addressing mode is placed
in either the A register or the X register, which is specified as part
of the instruction opcode. Operand 1 is an address that points to
a location in either the RAM memory space or the register space
that is the source for the instruction. Arithmetic instructions
require two sources; the second source is the A register or X
register specified in the opcode. Instructions using this
addressing mode are two bytes in length.
Examples 
9.2.3  Source Indexed
The result of an instruction using this addressing mode is placed
in either the A register or the X register, which is specified as part
of the instruction opcode. Operand 1 is added to the X register
forming an address that points to a location in either the RAM
memory space or the register space that is the source for the
instruction. Arithmetic instructions require two sources; the
second source is the A register or X register specified in the
opcode. Instructions using this addressing mode are two bytes
in length.
Examples
9.2.4  Destination Direct
The result of an instruction using this addressing mode is placed
within either the RAM memory space or the register space.
Operand 1 is an address that points to the location of the result.
The source for the instruction is either the A register or the X
register, which is specified as part of the instruction opcode.
Arithmetic instructions require two sources; the second source is
the location specified by Operand 1. Instructions using this
addressing mode are two bytes in length.
Examples
Table 9-7.  Source Immediate
Opcode
Operand 1
Instruction
Immediate Value
ADD
A,
7
;In this case, the immediate value of 7 is added 
with the Accumulator and the result is placed in 
the Accumulator.
MOV
X,
8
;In this case, the immediate value of 8 is moved 
to the X register.
AND
F,
9
;In this case, the immediate value of 9 is logically 
ANDed with the F register and the result is placed 
in the F register.
Table 9-8.  Source Direct
Opcode
Operand 1
Instruction
Source Address
ADD
A,
[7]
;In this case, the value in the RAM 
memory location at address 7 is added 
with the Accumulator, and the result is 
placed in the Accumulator.
MOV
X,
REG[8]
;In this case, the value in the register 
space at address 8 is moved to the X 
register.
Table 9-9.  Source Indexed
Opcode
Operand 1
Instruction
Source Index
ADD
A,
[X+7]
;In this case, the value in the memory 
location at address X + 7 is added with 
the Accumulator, and the result is 
placed in the Accumulator.
MOV
X,
REG[X+8]
;In this case, the value in the register 
space at address X + 8 is moved to the 
X register.
Table 9-10.  Destination Direct
Opcode
Operand 1
Instruction
Destination Address
ADD
[7],
A
;In this case, the value in the memory 
location at address 7 is added with the 
Accumulator, and the result is placed 
in the memory location at address 7. 
The Accumulator is unchanged.
MOV
REG[8],
A
;In this case, the Accumulator is 
moved to the register space location at 
address 8. The Accumulator is 
unchanged.