2. Cabling
2-9
Alarm Interface
The ALARM interface consists of five contacts. Three of the contacts provide 
access to alarm relays that that can be used to set off Major and Minor physical 
alarms. The other two contacts provide access to a sense circuit that can be used 
to detect the open or closed condition of an external alarm relay.  
A 5-position plug provided in the hardware kit is used to connect 20–28 AWG wire 
to the ALARM terminal block (see 
The contacts are closed during normal operation. They open in response to loss of 
power, hardware failure, or other alarm conditions. See 
 in 
 for more information.
CAUTION:
The ALARM Sense + and Sense – contacts are intended to be connected 
to an external alarm relay. Do not apply power to these contacts; doing so 
will result in damage to the unit.
Procedure
To connect the ALARM interface:
1. Strip the tips of the alarm source wires about 1/2 inch (13 mm).
2. Use a screwdriver to press the orange spring tab in while inserting the wire 
into the hole below it. The insulation should be fully within the plug and no 
bare wire should be exposed outside of the plug.
3. Insert the plug into the ALARM interface on the front panel of the 
BitStorm 2600.
4. If the BitStorm 2600 is in a rack, dress the cable to the left and secure it to the 
rail with a cable tie. 
5. Connect the other end of the cable to your alarm monitoring system.
02-17328
Spring
Tab