1-14 
About the Vanguard 6435/6455
Vanguard 6455 Requirements for Bisync
Vanguard 6455 Requirements for Bisync
Vanguard 6455 
Requirements
The guidelines below are required when using the BSC 3270-to-SNA Conversion 
feature:
• 32 Meg SIMM Memory Module
• Local Dynamic Port Creation Heap Size needs to be configured for Bisync 
and AS/400
Note
When setting the Local Dynamic Port Creation Heap Size, refer to the Ease of 
Configuration information located in the following section. A copy of your 
current configuration files should be saved before changing the Local Dynamic 
Port Create Heap Size.
BSC 3270-to-SNA 
Conversion 
Increase 
Parameters to 
Maximum Value
The following Node Record Parameters need to be increased in order to 
accommodate increasing the number of SNA to Bisync 3270 Devices to 256:
• Mnemonic Table Size
• Quantity of DSP Devices
• Maximum Simultaneous Calls
The Frame Relay Station or X.25 Port parameter; Number of Two Way Simultaneous 
Calls, needs to be increased in order to accommodate increasing the number of SNA 
to Bisync 3270 Devices to 256. Maximum number of SLAC Stations supported for 
BSC/LU Devices on a Vanguard 6455 is 20.
BSC 2780/3780-to-
SNA/LU0 
Conversion 
Increase 
Parameters to 
Maximum Value
The following Node Record Parameters need to be increased in order to 
accommodate increasing the number of SNA 3780 remote ports to 256:
• Mnemonic Table Size
• Quantity of SES 3780 remote ports
• Maximum Simultaneous Calls
The Frame Relay Station or X.25 Port parameter; Number of Two Way Simultaneous 
Calls, needs to be increased in order to accommodate increasing the number of 3780 
conversion stations to 256.