Installation and Replacement 
3-25
Modifying Your Vanguard 6435/6455
Adding/Removing 
a FLASH/Data 
Compression/
Encryption SIMM
Figure 3-13 shows how to add or remove a FLASH or Data Compression SIMM for 
the Vanguard 6435/6455. Refer to Figure 3-10 for the location of the SIMM slots:
• Data Compression SIMM or Encryption SIMM: Slot U108
• FLASH SIMM: Slot U57
Caution
Be careful when installing a Data Compression SIMM or a FLASH SIMM. These 
SIMM slots look identical and you may accidently place a SIMM in the wrong 
SIMM slot which could damage the equipment.
Caution
Some components used in the 6435/6455 are sensitive to static electric discharges; 
static electric discharges can cause damage to internal components. Use proper 
handling and grounding precautions whenever handling cards and components.
Mise en Garde
Certains composants du 6435/6455 sont sensibles aux décharges électrostatiques qui 
peuvent les endommager. Prenez les dispositions et précautions de mise à la terre 
nécessaires lors de la manipulation de cartes et de composants.
Vorsicht
Einige im 6435/6455 verwendeten Komponenten sollten keinen elektrostatischen 
Entladungen ausgesetzt werden, durch die interne Bauteile beschädigt werden 
können. Wenden Sie die entsprechenden Maßnahmen zur Erdung und zum Schutz 
vor statischen Ladungen bei der Handhabung von Karten und Komponenten an. 
Note
The location of the Data Compression (DCC/DSP) SIMM/Encryption SIMM 
and the FLASH SIMM are indicated on the motherboard as shown in 
Figure 3-13.