ASI-IP-GTW User's Manual 
 
 Page 
19 
The unit is supplied with a two meter detachable power supply cable 
equipped with the moulded plug suitable for Europe, UK or US. 
The wires in the mains cable are coloured in accordance with the wire 
colour code shown in Table 3. 
 
Table 3. Supply Cable wiring colours 
1.1.1.16 Protective Earth /Technical Earth 
The unit has a Technical Earth terminal located at the rear panel. Its 
use is recommended. This is not a Protective earth for electrical shock 
protection. The terminal is provided to: 
1.  Ensure all equipment chassis fixed in the rack are at the same 
Technical earth potential. To achieve this, connect a wire between 
the Technical earth terminal and a suitable point on the rack.  
2.  Eliminate the migration of stray charges when connecting between 
equipment. 
Warning: If the moulded plug fitted to the mains cable supplied with 
this unit is not required, please dispose of it safely. Failure to do this 
may endanger life as live ends may be exposed if the removed plug is 
inserted into a mains outlet.  
Caution: Power supply cords should be routed so that they are not 
likely to be walked on or pinched by items placed upon or against 
them, paying particular attention to cords at plugs, convenience 
receptacles, and the point where they exit from the appliance. 
 
UK (BS 1363) 
EUROPE (CEE 7/7) 
USA (NEMA 5-15P) 
Earth: 
Green-and yellow 
Green-and yellow 
Green 
Neutral:    
Blue               
Blue              
White 
Live:   
Brown              
Brown             
Black   
To achieve protection against earth faults in the installation, connected 
to the equipment by signal cables etc., the equipment should always be 
connected to protective earth. If the mains appliance coupler is 
disconnected while signal cables are connected to the equipment, earth 
connection should be achieved by connecting earth to the additional 
technical earth connection on the rear panel of the unit. 
Warning: This unit must be correctly earthed through the moulded 
plug supplied. If the local mains supply does not have an earth 
conductor do not connect the unit. 
Caution: Consult the supply requirements in  
Appendix B: Technical Specification prior to connecting the unit to the 
supply.