NEC NDA-30115-001 ユーザーズマニュアル
NDA-30115 Revision 1.0
Page 35
Property Management System - Communication Interface
Message Formats
Guest Room
Figure 4-4 Guest Room (General)
Message fields are:
•
FC -- Function Codes that use this message format are: (FTC-FC)
•
51-1 -- Guest Room 1 (Model 90)
•
51-2 -- Guest Room 2 (Model 90)
•
51-3 -- Guest Room 3 (Model 90)
•
51-4 -- Guest Room 4 (Model 90)
•
51-5 -- Guest Room 5 (Model 90)
•
51-6 -- Guest Room 6 (Model 90)
•
51-7 -- Guest Room 7 (Model 90)
Note:
This message was not previously defined in NEAX2400 IMS Hotel System PMS
Interface Specification.
Interface Specification.
•
Extension -- Extension number. If the extension number is less than six digits,
left justify the number and fill the remaining bytes with space (20H) characters.
left justify the number and fill the remaining bytes with space (20H) characters.
•
Maid -- Identification number of the maid. If the maid identification number is
less than six digits, left justify the number and fill the remaining bytes with
space (20H) characters.
less than six digits, left justify the number and fill the remaining bytes with
space (20H) characters.
•
LEN -- Line Equipment Number.
** Multiple Function Codes use this message. See below.
LEN
‘5’
‘1’ ‘2’
‘3’
** Extension
Maid
0
1
2
3
4
6
8
9
15
STX
SA
UA
EI
FTC
MSC
FC
6
6
02H ‘1’
‘!’
‘L’
03H xx
ETX BCC
21
27
28
6