Nortel Networks NN44200-313 ユーザーズマニュアル

ページ / 66
Defining CallPilot in the customer data block (LD 15)
21
4
Enter the appropriate values as described in the following table to
define Call Redirection. For prompts not listed in the following table,
press Enter to accept the default.
Table 6
LD 15 - Configuring Call Redirection
Prompt
Response
Notes
REQ
CHG
TYPE
rdr
CUST
xx
Customer number for CallPilot.
FNAD
xxxx
Enter the FDN for CallPilot.
FNAT
xxxx
Enter the FDN for CallPilot.
FNAL
xxxx
Enter the FDN for CallPilot.
CFNA
4
CFN0
1-(4)-15
Number of normal ringing cycles
for CFNA, Option 0.
CFN1
1-(4)-15
Number of normal ringing cycles
for CFNA, Option 1.
CFN2
1-(4)-15
Number of normal ringing cycles
for CFNA, Option 2.
5
Enter the appropriate values as described in the following table to
define End-to-End Signaling Tone. For prompts not listed in the
following table, press Enter to accept the default.
Table 7
LD 15 - Configuring End-to-End Signaling Tone
Prompt
Response
Notes
REQ
CHG
TYPE
ftr
CUST
xx
Customer number for CallPilot.
EEST
YES
NO
Enter NO if remote sites are set
to NO.
6
Enter the appropriate values as described in the following table to
define Integrated Services Digital Network. For prompts not listed in
the following table, press Enter to accept the default.
Nortel CallPilot
Quickstart Guide
NN44200-313
01.02
Standard
5.0
19 May 2008
Copyright © 2007-2008, Nortel Networks
.