Nortel Networks R2MFC ユーザーズマニュアル
Chapter 7 Command Line Interface (CLI) 81
R2MFC Media Bay Module Installation and Configuration Guide
ALarm directory
Table 23 includes the CLI commands for alarm configuration and status. The commands are
accessed from the ALarm directory.
accessed from the ALarm directory.
Table 23 ALarm directory CLI commands (Sheet 1 of 2)
CLI command
Description
G1Res <link_no> <group I alarms>
Resets Group 1 alarm counters.
Where:
link_no is the link number, either 0 or 1.
Group I alarms defines the group and can have values of:
•
link_no is the link number, either 0 or 1.
Group I alarms defines the group and can have values of:
•
0 – BPV
•
1 – FBER
•
2 – SLIP
•
3 – CRC4
•
4 – ALL
Bit3 <link_no> <bit3>
Used for bit 3 option handling.
Where:
link_no is the link number, 0 or 1.
bit3 is the option flag, 0 (off) or 1 (on).
link_no is the link number, 0 or 1.
bit3 is the option flag, 0 (off) or 1 (on).
OP16 <link_no> <AIS
TS16
>
Used for AIS
TS16
option handling.
Where:
link_no is the link number, 0 or 1.
AIS
link_no is the link number, 0 or 1.
AIS
TS16
is the option flag, 0 (off) or 1 (on).
FR <link_no> <fr_mode>
Changes the frame mode.
Where:
link_no is the PCM link number, 0 or 1.
fr_mode is 0 (ALTRNT2_FRM) or 1 (MULTIFRM_CRC4)
link_no is the PCM link number, 0 or 1.
fr_mode is 0 (ALTRNT2_FRM) or 1 (MULTIFRM_CRC4)
Default for link 0 (external) depends on country selection. Default for link 1
(internal) is set to alternate and should not be changed to multframe.
G1th <link_no> <pra> <limcount>
Sets the group I alarm thresholds.
Where:
link_no is the PCM link number, 0 or 1.
pra is the problem group I errors and can have values of:
•
link_no is the PCM link number, 0 or 1.
pra is the problem group I errors and can have values of:
•
0 – BPV
•
1 – FBER
•
2 – SLIP
•
3 – CRC4
limcount is the threshold error count in the range of 1...1000.