M5317 BRI Terminal
Restricted powering
A second dip switch (switch B), in the same location and accessible through 
the same access hatch as switch A must be set to determine whether the 
telephone accepts restricted powering from PS1 or PS2. As a rule, only one 
telephone on a loop is designated for restricted powering and is named the 
“designated” telephone. When an NT1 or line card reverses the polarity of the 
PS1 or PS2 power output while operating from backup batteries, only a 
“designated telephone” continues to operate.
Power consumption
The normal standby mode power consumption indicated below depends on 
deactivating the S/T-loop (not currently supported).
Operating Mode
M5317TX
M5317TDX 
Normal active
 1.2.2W
1.5W
Normal standby 
200mW
250mW
Voltage range
The following are the operating limits when attached to an S/T-loop:
24 V - Minimum DC input voltage at the line cord when the loop is full loaded 
(PS2)
56.5 V - Maximum DC input voltage at the line cord when the loop is not 
loaded (PS2)
Local power supply requirements
The following values apply to sealed plug-in AC transformers with rectified 
DC output, used for local power supply from a wall-outlet directly at the 
working location of the telephone.
Australia
Minimum AC voltage at outlet: 200 V rms
Maximum AC voltage at outlet: 280 V rms
Average maximum AC current required: 50 mA
AC supply frequency: 50 Hz
Minimum transformer output voltage: 24 V DC
Maximum transformer output voltage: 34 V DC