Lucent Technologies Network Access Module ユーザーズマニュアル

ページ / 75
INA Module Maintenance Options
C-4
INA Module Installation and Configuration Guide
Note – The additional error event counts are cleared whenever the INA module is reset. 
Be sure to view the error events before resetting the module or busying out the module.
From your system programming console, use the following sequence to access the INA 
module Error Events screen. Be sure to select the corresponding INA module slot 
number.
Menu: Maintenance
Slot
Slot#
Enter
Error Events
The Current Hour and Previous Hour error event screens that are also used on the 100D 
module are available on the INA module. Clearing the new error event counts does not 
affect the Current Hour and Previous Hour error event counts. Because the Current 
Hour and Previous Hour statistics are computed with a different algorithm, Current 
Hour and Previous Hour counts do not match the newer counts.
24 Hour Event Totals
The 24-hour total error event screen reports cumulative error statistics spanning the 
past 24 hours. The current event totals are not included in this report. From your 
system programming console, use the following sequence to access the INA 24 Hr Total 
screen. Be sure to select the corresponding INA module slot number.
Menu: Maintenance
Slot
Slot#
Enter
Error Events
24 hr total
This screen provides statistics related to the health of the T1/PRI interface. These 
statistics are summarized in Table C-3.
Table C-3
24-Hour Total Error Line Items
Item
Description
24 Hour Slot xx
xx is the slot currently being reported on. 
nn Valid 
Intervals 
nn is the number of valid historical 15-minute 
intervals from the past 24 hours. A valid historical 
interval is one for which data has been captured while 
the system was running. During a valid interval, data 
has not been lost due to a clearing of error events or a 
board reset. A board reset can occur during a reset, 
busy-out, frigid start, cold start or power outage.
MIS
Misframes. 
SLP
Slips.
ES
Errored Seconds.
BS
Bursty errored seconds
.
SEC
Severely errored seconds.
FS
Failed seconds.
BPV