RAD Data comm RIC-155 ユーザーズマニュアル

ページ / 90
RIC-155 Installation and Operation Manual 
Chapter 4  Configuration 
 
Configuring the RIC-155 for Operation 
4-7 
 
To display the System Configuration menu: 
•  From the Configuration menu, select System Configuration
The System Configuration menu appears (see 
 
Procedures for alarm configuration and masking are detailed in 
Chapter 5
 
RIC-155 
System  
1. Master clock  
2. Management   > 
3. Control port  
4. Alarm Configuration 
5. Factory default  
6. Reset Device 
 
Please select item <1 to 5> 
 
ESC-prev.menu; !-main menu; &-exit 
Figure 4-9.  System Configuration Menu 
Configuring the Clock Source 
RIC-155 supports internal and loopback clock modes.  
 
To configure the clock source: 
•  From the System Configuration menu, select Master Clock
Display is refreshed and a new master clock value appears: Internal or 
Loopback
Configuring Control Port Parameters 
RIC-155 embedded software enables you to configure the serial port parameters, 
which include specifying terminal baud rate, defining user name, password and 
log-off time, and enabling or disabling pop-up alarms. 
 
To access the Control port menu: 
•  From the System Configuration menu, select Control Port
The Control Port menu appears (see 
RIC-155 
Control Port 
1. Baud Rate   
>(9600) 
2. Pop Alarm    
(OFF) 
3. Security Timeout 
(10 min) 
4. Save All 
 
Please select item <1 to 4> 
 
ESC-prev.menu; !-main menu; &-exit 
 
Figure 4-10.  Control Port Menu 