Promise Technology TX4000 ユーザーズマニュアル

ページ / 76
Chapter 3: FastBuild Configuration Utility 
 
 
21 
Manually Creating an Array  
The Define Array (3) option from the Main Menu allows users to begin the 
process of manually defining the drive elements and RAID levels for one or 
multiple disk arrays attached to FastTrak TX4000.  
Users will commonly create one or two drive arrays with FastTrak TX4000, 
though the card will support a maximum of four arrays. You may use a single 
drive in striping mode with FastTrak TX4000. In this rare scenario, the card will 
create an individual array ID but will offer conventional controller performance 
depending on the drive type. At a later time, you can add a second drive to the 
array and recreate the array to support RAID 1 mirroring. 
Note 
 
For most installations, Promise recommends the (1) Auto 
Setup for easy disk array creation. 
 
 
FastBuild (tm) Utility 1.xx (c) 2002-2005 Promise Technology, Inc. 
[Define Array Menu] 
 
  Array No 
RAID Mode 
Total Drv 
Capacity(MB)  
Status 
  Array 1 
Stripe 
16126 
Functional 
  Array 2 
—— 
—— 
—— 
—— 
  Array 3 
—— 
—— 
—— 
—— 
  Array 4 
—— 
—— 
—— 
—— 
[ Keys Available ] 
Note: * — Bootable Array 
 
[
] Up [
] Down   [ESC] Exit   [Enter] Select   [Space] Change Boot Drive 
 
 
To manually create an array from the Define Array Menu: 
1. 
Press the arrow keys to highlight the array number you wish to define, and 
press Enter to select.  
2. 
The Define Array Definition Menu will next appear that allows drive 
assignments to the disk array (see next page).