Grandstream Networks HandyTone-496 ユーザーズマニュアル
HandyTone-496 User Manual
Grandstream Networks, Inc
.
30
Voice Frames per
TX
TX
This field contains the number of voice frames to be transmitted in a single
packet. When setting this value, the user should be aware of the requested
packet time (used in SDP message) as a result of configuring this parameter.
This parameter is associated with the first vocoder in the above vocoder
Preference List or the actual used payload type negotiated between the 2
conversation parties at run time.
e.g., if the first vocoder is configured as G723 and the “Voice Frames per TX”
is set to be 2, then the “ptime” value in the SDP message of an INVITE request
will be 60ms because each G723 voice frame contains 30ms of audio.
Similarly, if this field is set to be 2 and if the first vocoder chosen is G729 or
G711 or G726, then the “ptime” value in the SDP message of an INVITE
request will be 20ms.
If the configured voice frames per TX exceeds the maximum allowed value, the
HandyTone ATA will use and save the maximum allowed value for the
corresponding first vocoder choice. The maximum value for PCM is 10(x10ms)
frames; for G726, it is 20 (x10ms) frames; for G723, it is 32 (x30ms) frames;
for G729/G728, 64 (x10ms) and 64 (x2.5ms) frames respectively.
packet. When setting this value, the user should be aware of the requested
packet time (used in SDP message) as a result of configuring this parameter.
This parameter is associated with the first vocoder in the above vocoder
Preference List or the actual used payload type negotiated between the 2
conversation parties at run time.
e.g., if the first vocoder is configured as G723 and the “Voice Frames per TX”
is set to be 2, then the “ptime” value in the SDP message of an INVITE request
will be 60ms because each G723 voice frame contains 30ms of audio.
Similarly, if this field is set to be 2 and if the first vocoder chosen is G729 or
G711 or G726, then the “ptime” value in the SDP message of an INVITE
request will be 20ms.
If the configured voice frames per TX exceeds the maximum allowed value, the
HandyTone ATA will use and save the maximum allowed value for the
corresponding first vocoder choice. The maximum value for PCM is 10(x10ms)
frames; for G726, it is 20 (x10ms) frames; for G723, it is 32 (x30ms) frames;
for G729/G728, 64 (x10ms) and 64 (x2.5ms) frames respectively.
Fax Mode
T.38 (Auto Detect) FoIP by default, or Pass-Through (must use codec
PCMU/PCMA)
PCMU/PCMA)
Dial Plan Prefix
Sets the prefix added to each dialed number
Use # as
Send Key
Send Key
This parameter allows users to configure the “#” key to be used as the “Send”
(or “Dial”) key. If set to “Yes”, pressing this key will immediately trigger the
sending of dialed string collected so far. In this case, this key is essentially
equivalent to the “(Re)Dial” key. If set to “No”, this “#” key will then be
included as part of the dial string to be sent out.
(or “Dial”) key. If set to “Yes”, pressing this key will immediately trigger the
sending of dialed string collected so far. In this case, this key is essentially
equivalent to the “(Re)Dial” key. If set to “No”, this “#” key will then be
included as part of the dial string to be sent out.
Subscribe for MWI: Default is No. When set to “Yes” a SUBSCRIBE for Message Waiting
Indication will be sent periodically.
Send Anonymous
If this parameter is set to “Yes”, the “From” header in outgoing INVITE
message will be set to anonymous, essentially blocking the Caller ID from
displaying.
message will be set to anonymous, essentially blocking the Caller ID from
displaying.
Special Feature
Default is Standard. Choose the selection to meet some special requirements
from Soft Switch vendors like Lucent FS5000 Simple Endpoint, CBCOM, etc.
from Soft Switch vendors like Lucent FS5000 Simple Endpoint, CBCOM, etc.
6.2.4 Saving the Configuration Changes
Once a change is made, users should click on the “Update” button in the Configuration page. The
HandyTone-496 will then display the following screen to confirm that the changes have been saved.