Zhone Technologies 900 ユーザーズマニュアル

ページ / 240
4-6 
Server Cards
Model No.
Running Head
ACS-ATM Card User Screens and Settings
ATM Card
TX-LBO (DS3)
If the distance between the DS3 switch and the system unit is short (less than 225 feet), signal 
attenuation may be needed. The Transmit Line Build-Out setting activates this feature. The 
options are off for distances greater than 225 feet, and on for distances less than 225 feet.
IDLE-UASN (DS3)
The Idle-Unassigned Cells setting will show if idle or unassigned cells should be sent when 
actual data is not being sent. The options are idle and uasn.
4.3.2
User Network Interface Screen (UNI)
The UNI Screen is used to set up the ATM UNI link. Figure 4-2 shows a typical UNI Screen. 
To go to that screen, press “n” (uNi command) in the ACS-ATM Card Main Screen. Table 4-3 
lists the possible actions you can perform from the UNI Screen, and Table 4-4 lists the option 
settings and defaults.
Figure 4-2. Typical UNI Screen