C O M M A N D   L I N E   I N T E R F A C E
Command Summary
350-7951
Quadra User’s Guide
60
. .
 . 
.
INputLOAD
<input #>  <1…160>
Loads the indicated entry from the Timing List to 
the specified input channel.  Timing list entries from 
1 to 99 are reserved for factory defined timing 
parameters.  Entries from 100 to 160 are available 
for user defined timing entries.
The entry is loaded only if it matches the measured 
signal parameters — sync format and polarity, 
interlace state, vertical total, and horizontal 
frequency. 
INputNAME 
<input #> [timing set 
name]
Names the specified input. The argument can be up 
to 23 alphanumeric characters with no spaces (use 
underscore for space).
Default:  
Auto_1
INputPHASE
<graphics input#> [0 … 31]
Adjusts the phase of the Analog/Digital Converter 
to optimize picture quality.  Applies to Analog RGB 
inputs only.
Default:  
24
INputSAVE 
<input#>  <100…160> 
Saves the input timing parameters for the specified 
input to the selected entry in the Input List.  
Whenever a signal is applied to the graphics input 
the signal parameters are measured and compared to 
entries in the list.  When a match is found it is 
applied to the 
Quadra
.
INputSouRCe
<input#> [RGB | DVI | 
YUV | COMPOSITE1 | 
COMPOSITE2 | SVIDEO]
Selects the analog or digital graphics source for the 
specified input.  
Default:  
RGB
INputTiMing
<input #> [<hfp> <hs> 
<hbp> <hact> <vfp> <vs> 
<vbp> <vact>] | [HFP | HS 
| HBP | HACT | VFP | VS | 
VBP | VACT] [value]
Defines the active area of the input signal and the 
selected input’s timing.  Using this command, the 
user can set all timing parameters as query or set the 
value of an individual parameter.  For example to 
query the value of vertical sync width issue the 
command 
INTM VS
.
Horizontally, the active part of the signal is 
<hact>
.  The inactive part (h blanking) is 
<hfp> 
+ <hs> + <hbp>
.  The total number of pixels 
horizontally is 
htotal
 = (h blanking) + 
<hact>
.  
Note that the pixel clock frequency = 
hfreq x 
htotal
 so changing the total horizontal pixel 
count (
htotal
) will directly change the frequency 
of the sample clock.
The active part of the vertical component of the 
signal is 
<vact>
.  The inactive part (v blanking) is 
<vfp> + <vs> + <vbp>
.  The total number of 
lines is 
vtotal
 = (v blanking) + 
<vact>
. Since 
Quadra
 knows the total line count an error will 
result if the sum of the active and inactive parts 
entered in the command do not match the measured 
total line count.
Refer to the “
” section for 
details on timing parameters.
Table 4-3. 
Input Commands Descriptions(Continued)
Command
Arguments
Description