 User Guide Integrated Lights-Out 
 
4.  Enter your Login Name>Password and click Find. 
IMPORTANT:  The HPQLOMIG wizard assumes a common user name 
and password for management processors are employed. If unique user 
names and passwords are used, the command line version of the 
migration utility should be used. 
 
Upgrading Firmware on Management Processors 
The upgrade firmware screen enables you to update the management processors 
to the firmware version that supports directories. This screen also enables you to 
designate the location of the firmware image for each management processor by 
either typing the path or clicking Browse. 
IMPORTANT:  Binary images of the firmware for the management 
processors are required to be accessible from the system that is running 
the migration utility. These binary images can be downloaded from the 
H (
                         
Management Processor 
Minimum Firmware Version 
RILOE 2.50 
RILOE II 
1.10 
iLO 1.40 
 
The upgrade process might take a long time, depending on the number of 
management processors selected. The firmware upgrade of a single management 
processor can take as long as five minutes to complete. If an upgrade fails, a 
message is displayed in the Results column and HPQLOMIG continues to 
upgrade the other discovered management processors. 
IMPORTANT:  HP recommends testing the upgrade process and 
verifying the results in a test environment before running the utility on a 
production network. An incomplete transfer of the firmware image to a 
management processor could result in having to locally reprogram the 
management processor using a floppy diskette. 
To upgrade the firmware on your management processors: 
1.  Select the management processors to be upgraded. 
2.  For each discovered management processor type, enter the correct pathname 
to the firmware image or browse to the image.