Group Administration and iLO Scripting 
In This Section 
Lights-Out Configuration Utility................................................................................................
 
 
Lights-Out Configuration Utility 
The Lights-Out Configuration Utility (CPQLOCFG.EXE) is a Windows®-based 
utility that connects to iLO using a secure connection over the network. RIBCL 
scripts are passed to iLO over the secure connection to CPQLOCFG. This utility 
requires a valid user ID and password with the appropriate privileges. The 
CPQLOCFG utility can be launched from Insight Manager 7 or Systems Insight 
Manager for Group Administration or used independently from a command 
prompt for batch processing. This utility can be downloaded from the HP website 
(
Version 2.20 or later of CPQLOCFG.EXE is required to configure iLO Directory 
Settings using RIBCL scripts. 
Insight Manager 7 and System Insight Manager discover iLO devices as 
management processors. The Lights-Out Configuration Utility sends a RIBCL 
file to a group of iLO processors to manage the user accounts for those iLO 
processors. iLO processors then perform the action designated by the RIBCL file 
and send a response to the log file. 
The Lights-Out Configuration Utility is used to execute RIBCL scripts on iLO 
and must reside on the same server as Insight Manager 7 or Systems Insight 
Manager. The Lights-Out Configuration Utility generates two types of error 
messages: runtime and syntax.  
• 
Runtime errors occur when an invalid action is requested. Runtime errors are 
logged to the following directories: