Remote Insight Command Language 
313 
 
MOD_BLADE_RACK Runtime Errors 
The possible MOD_BLADE_RACK error messages include: 
• 
• 
• 
• 
• 
Rack information is open for read-only access. Write access is required for 
this operation. 
Rack Name too long. 
Enclosure Name too long. 
Bay Name too long. 
User does not have correct privilege for action. CONFIG_ILO_PRIV 
required. 
 
GET_DIAGPORT_SETTINGS 
The GET_DIAGPORT_SETTINGS command requests the respective iLO 
diagnostic port settings. For this command to parse correctly, the 
GET_DIAGPORT_SETTINGS command must appear within a RACK_INFO 
command block, and RACK_INFO MODE can be set to read or write. 
Example: 
<RIBCL VERSION="2.0"> 
<LOGIN USER_LOGIN="adminname" PASSWORD="password"> 
<RACK_INFO MODE="read"> 
<GET_DIAGPORT_SETTINGS/> 
</RACK_INFO> 
</LOGIN> 
</RIBCL> 
 
GET_DIAGPORT_SETTINGS Parameters 
None 
 
GET_DIAGPORT_SETTINGS Runtime Errors 
None