HP (Hewlett-Packard) HP Integrated Lights-Out ユーザーズマニュアル

ページ / 410
32 
 User Guide Integrated Lights-Out 
 
On select p-Class blades in enclosures with updated management backplanes that 
support BL30P (high density) blades, iLO can be used for initial enclosure static 
IP configuration. Initial configuration of the blade in bay 1 allows all subsequent 
iLOs in the enclosure to receive predetermined static IP assignments. This 
feature is supported in iLO 1.55 and later. 
 
Static IP Bay Configuration 
Static IP bay configuration, implemented using the new Static IP Bay Settings on 
the BL p-Class tab, eases the initial deployment of an entire enclosure or the 
subsequent deployment of blades within an existing enclosure. While the 
preferred method for assigning IP addresses the iLO to each blade is through 
DHCP and DNS, these protocols are not always available on non-production 
networks. 
Static IP bay configuration automates the first step of BL p-Class blade 
deployment by enabling the iLO management processor in each blade slot to 
obtain a predefined IP address without relying on DHCP. iLO is immediately 
accessible for server deployment using Virtual Media and other remote 
administration functions. 
Static IP bay configuration uses the Static IP Bay Configuration addressing 
method which enables you to assign IP addresses to each iLO based on slot 
location in the respective server enclosure. By providing a set of IP addresses in 
the enclosure, you gain the advantages of a static IP bay configuration, without 
requiring each individual iLO to be configured locally. 
Using iLO static IP bay configuration: 
• 
• 
• 
• 
Helps avoid the costs of a DHCP infrastructure to support the blade 
environment 
Provides easier setup with automatic iLO address generation for all or a few 
selected bays 
 
ProLiant BL p-Class User Requirements 
Users must have the Configure iLO Settings privilege. 
A network connection to iLO must be available and functioning properly.