HP (Hewlett-Packard) TC3100 ユーザーズマニュアル

ページ / 121
 
A Event Codes 
The table below describes the event codes that can be listed in the event log and 
optionally directed to specified users via e-mail or pager. When the HP Server 
Remote Management Card sends notification about a server event, it includes the 
server identifying number and a five-digit code identifying the event. (If you use 
email or a TAP pager, you will receive the server name and some descriptive text 
as well.)  
Note that Server Agents software will need to be loaded on your server in order to 
receive an event notification for most of the events listed below. Refer to the HP 
Server SNMP agents documentation (viewable via the HP Server Documentation 
CD-ROM
) for agent installation and configuration instructions. Refer to the 
Readme file for Agents software located on the HP Netserver Navigator CD 
under manage\server. 
NOTE
 
It's a good idea to copy appropriate sections of this table and 
keep it with the pager you use to receive notifications. A 
regularly updated list of HP supported event codes is available 
on the hp site at: 
,  under the Server 
Troubleshooting section under Technical Support. 
Notification and log messages are limited to a length of 40 characters. 
 
Pager 
Code 
 
Server Event 
 
Severity 
001XX 
Temperature sensor crossed lower non-critical threshold 
WARNING 
001XX 
Temperature sensor crossed lower critical threshold 
CRITICAL 
001XX 
Temperature sensor crossed lower non-recoverable threshold 
CRITICAL 
001XX 
A temperature inside the server has gone outside the factory 
specified range. 
WARNING 
001XX 
A temperature inside the server has gone far outside the factory 
specified range. 
CRITICAL 
001XX 
Temperature sensor crossed upper non-recoverable threshold 
CRITICAL 
00261 
VRM failure 
CRITICAL 
002XX 
A measured voltage in the server has gone outside the factory 
specified lower voltage range. 
WARNING 
002XX 
A measured voltage in the server has gone far outside the factory 
specified lower voltage range. 
CRITICAL 
55